Angularity symbol svg Angularity can mean two very different things depending on which reference feature it is called out on. Surface Angularity is a tolerance that controls the orientation and form of a surface with respect to a datum at a specified angle. Axis/Midplane Angularity controls the relationship of a datum and an axis or midplane to a specific angle with respect to one another.

 

Angularity Symbol and Callout 

Angularity symbol

Surface Angularity: 

Angularity is a less common symbol that requires the referenced planar surface to be at a specific angle to a datum. The tolerance zone is orientated at that angle from the datum, in which the surface referenced must lie within. The tolerance value is a distance (inches or millimeters) and creates a zone that the surface in question will have to be within. 

Feature of Size Angularity: 

An axis can also be controlled with Angularity. When referenced on a circular feature, the feature control frame will contain the diameter symbol (Ø). Axis Angularity can be applied to an external feature (pin/boss) or an internal feature (hole). When Angularity is referenced for axial control of a feature of size, it specifies a cylindrical tolerance zone orientated at a specific angle from the datum.  

A midplane can also be controlled with Angularity. Angularity can be applied to any internal or external width feature. Additionally, MMC (maximum material condition) can be used on Midplane/Axis Angularity to enable easier gaging of the part.  

Angularity Tolerance Zone 

Surface:

The tolerance zone shape is two parallel planes orientated at a specific angle to a datum and ensures that the entire feature falls within the tolerance zone. This zone controls the orientation of the surface as well as its form (flatness). 

Surface Angularity Tolerance Zone

Remember: Angularity doesn’t control the angle of the referenced surface with degrees. The value within the feature control frame defines the width of a zone that the surface must reside within. 

Feature of Size:

For a cylindrical feature of size, the tolerance zone shape is a cylinder and it is orientated at a specific angle to the referenced datum. To pass the specification, the axis of the controlled feature must remain within that cylindrical tolerance zone. For midplanes (not pictured) being controlled with Angularity, the tolerance zone is two parallel planes spaced apart by the listed tolerance value and the midplane of the feature of size being controlled must remain within the two parallel planes. 

Axis Angularity Tolerance Zone

How to Inspect Angularity 

Surface

Surface Angularity Inspection

Surface angularity can be measured by using a height gage, similar to a flatness inspection. The difference is we are orientating that surface with respect to the referenced datum in a way that allows us to inspect it relative to the inspection equipment as well. 

Angularity measurement

The main requirement is that the indicator is translated on a plane that is at a specific angle to the datum simulator. The surface in question is then leveled to itself, and the deviations of the indicator are reported as angularity error.

Feature of Size

Similar to the surface inspection, when measuring angularity of a feature of size, we want to make sure the datum is simulated at a specific angle to the plane of inspection. This allows our inspection equipment to align to the appropriate orientations established by the referenced datums. Then we can use a physical simulator to establish and measure the axis of the feature to determine its worst-case deviations of orientation relative to the datum.

FOS Angularity Inspection

When the callout includes the MMC modifier, a functional gage (Go gage) can be used. The gage simulates the mating part — a pin of the virtual condition diameter is inserted into the hole while the part is seated on the datum. If the pin passes through while remaining at a specific angle to the datum simulators, the combined size and angularity requirements are satisfied. This is a pass/fail method and does not provide quantitative data. 

Remember, angularity CANNOT control the location of any feature. It only assesses the orientation of the feature. 

Example and When to Use Angularity

When to Use Angularity

Angularity is not a commonly used symbol. That is because most features are orthogonal (perpendicular and/or parallel) to other features. In those scenarios, those two symbols (perpendicularity and/or parallelism) would take precedence. Additionally, if a feature is at an odd angle to the rest of the part, position or profile of a surface will generally already be applied to that feature, thus already locking down the orientation of the feature. In rare scenarios, it might be necessary to refine ONLY the orientation of the feature without changing the location tolerance. In those scenarios, angularity can be appropriate too.  

Angularity Considerations  

Angularity is unique in the fact that it can be used to control a specific angle to one datum while being able to control perpendicularity to another one. This means that a single feature control frame may or may not reference 2 datums. Remember, angularity will NOT control the location at all.

We cover the intricacies of angularity, how it’s interpreted, how it’s inspected, and the miscellaneous things you should know about this symbol in our GD&T Fundamentals Course as well as our GD&T Inspection Course. These courses show you everything you need to know about angularity and then some!

Angularity course images



All Symbols